Innovative metering solutions for smart grids
Fiber Optical Current Transformers
for Digital substations

FIBER-OPTICAL CURRENT SENSOR FOR INDUSTRIAL APPLICATIONS IEC-61850-3 COMPLIANCE

DC SMELTERS CHEMICAL INDUSTRY HYDROGEN PRODUCTION

SUPERCONDUCTIVITY FUSION REACTORS REFERENCE MEASUREMENTS

TECHNICAL SPECIFICATIONS

Measuring principle
Measured current
Rated current
Precision
Recommended interval between calibrations
Digital output

Fiber optical based on Faraday effect, not affectable to external magnetic fields
DC, AC, DC+AC
From 10 up to 14 000kA
±0.1%, ±0.2%, ±0.5%, ±1.0%
6 years for ±0.2%, ±0.5%, ±1.0% accuracy
3 years for 0.1% accuracy
Modbus RTU IEA485

Logical outputs
Sampling rate
Dimensions

Open collector, configurable polarity and switching logic
Up to 14400 1/sec, configurable
Electronic unit (WxHxD, mm) 482x132x350, Front panel maintenance

Analog outputs

0..20mA/4..20mA/±0..20mA, configurable source, mode and rated current 0..1V/±0..1V, configurable source, mode and rated current

Electronic unit

Sensing element

Environment conditions
Power supply
IP rating

IEC 61850-3. T = 0 °C to +45 °C
24 20% VDC, 1A
IP20

IEC 61850-3. T = -40 °C to +70 °C
N/A. Passive fiber sensor
IP67

Sensing element

Temperature sensor

HMI panel display

ORDERING INFORMATION

Specification code

GMS-FCS-DC-AA-BB1CC1-BB2CC2-DD-EE-FF

GMS
FSC
DC

Green-metering solutions
Fiber-optical current sensor
For DC applications (no digital IEC 61850-9-2 sampling output)

AA

Quantity of measuring channels
1 One measuring channel
2 Two measuring channels

BB1

Precision in range of 10..100% of selectable rated current for first channel
01  ±1%
02  ±2%
05   ±5%
10   ±0%

CC1

Optical sensor limits for rated current range for first channel.
Option CR1-CR4 should be specified, combination of options available.

SR Standard range from 10 up to 350kA
ER Extended range from 100 up to 700kA
UR Ultra-high range from 800 up to 14000kA

DD

Type of analog and logical outputs (Digital ModbusRTU output always installed)
01 1 х (0..20mA/4..20mA/±0..20mA)
1 х (0..1V/±0..1V)
3 x logical
02 2 х (0..20mA/4..20mA/±0..20mA)
2 х (0..1V/±0..1V)
6 x logical

EE

Temperature range for sensors
01 25 °C to +55 °C
02 0 °C to +45 °C
03 –10 °C to +50 °C
04 –20 °C to +60 °C
05 –30 °C to +65 °C
06 –40 °C to +70 °C
IR Individual range, declared in specification

FF

Distance between Electronic unit and sensor in meters

Options

HMI
PS220DC
PS230AC
CR1
CR2
CR3
CR4

HMI display for panel mounting
DIN-rail power supply for electronic unit from 220VDC power source
DIN-rail power supply for electronic unit from 230VAC power source
Current range for sensor: from 0 to 25% of basic optical sensor limits range
Current range for sensor: from 25 to 50% of basic optical sensor limits range
Current range for sensor: from 50 to 75% of basic optical sensor limits range
Current range for sensor: from 75 to 100% of basic optical sensor limits range

Version PDF ------------->